🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Solar Panel to Charge Controller Adaptor Kit

Product image 1
Product image 2
Product image 3
Product image 4
Product image 5
Product image 6
Product image 7
Product image 8
Product image 9
Product image 10
Product image 11
Product image 12
Product image 13
Product image 14
Product image 15

Solar Panel to Charge Controller Adaptor Kit

Ā 

Description

The Renogy Adaptor Kit is a set of two wires designed specifically for connecting a Renogy solar panel to a charge controller. The Adaptor Kit includes solar connectors on one end for effortless connection to the solar panel, and exposed wire on the other end to lead directly into the charge controller. This wiring kit is essential for off-grid solar installations, roof or ground level, and is offered in a wide range of sizes. The wiring is weatherproof and designed to withstand extreme heat and cold. This wiring kit is ideal for Renogy Off-Grid Kits ranging from 100W to 400W.

Renogy offers a wide range of lengths, as well as two different gauge sizes to choose from. The different sizes allow for customization based on a customer's unique needs. The Renogy 10ft 10AWG Adaptor Kit allows for 10 feet of length between the solar panel and charge controller.

Ā 

NOTE

  • If you have any questions regarding this product, please call us at 1 (909) 287-7111 or or contact us for troubleshooting assistance.
  • More questions about your off-grid power system? Learn more from Renogy Learning Center

Key Features

  • Hard plastic connectors at each end.
  • Female and male connectors for an unbreakable connection.
  • Weatherproof, insullated wiring.
  • Exposed ends for connection to the solar charge controller.
  • Essential for off-grid solar power system setup.
  • Black sunlight resistant cable.
  • Extends and locks built-in cables.
Ā 

Package Includes

Ā 

Renogy Solar Adaptor Kit

1 x

Ā 

Ā 
Renogy 10ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 10ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 10ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 10ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 20ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 20ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 20ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 20ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 30ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 30ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 30ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 30ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 40ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers(A Pair) Ā 
Length: 40ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 40ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 40ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 9in 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 9in AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 9in 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 9in AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Ā 

Warranty Information

Accessories 1-year material and workmanship warranty
Ā 
Ā 

Select Cable Length
Select Cable Size
From $7.00

Original: $19.99

-65%
Solar Panel to Charge Controller Adaptor Kit—

$19.99

$7.00

Product Information

Shipping & Returns

Description

Ā 

Description

The Renogy Adaptor Kit is a set of two wires designed specifically for connecting a Renogy solar panel to a charge controller. The Adaptor Kit includes solar connectors on one end for effortless connection to the solar panel, and exposed wire on the other end to lead directly into the charge controller. This wiring kit is essential for off-grid solar installations, roof or ground level, and is offered in a wide range of sizes. The wiring is weatherproof and designed to withstand extreme heat and cold. This wiring kit is ideal for Renogy Off-Grid Kits ranging from 100W to 400W.

Renogy offers a wide range of lengths, as well as two different gauge sizes to choose from. The different sizes allow for customization based on a customer's unique needs. The Renogy 10ft 10AWG Adaptor Kit allows for 10 feet of length between the solar panel and charge controller.

Ā 

NOTE

  • If you have any questions regarding this product, please call us at 1 (909) 287-7111 or or contact us for troubleshooting assistance.
  • More questions about your off-grid power system? Learn more from Renogy Learning Center

Key Features

  • Hard plastic connectors at each end.
  • Female and male connectors for an unbreakable connection.
  • Weatherproof, insullated wiring.
  • Exposed ends for connection to the solar charge controller.
  • Essential for off-grid solar power system setup.
  • Black sunlight resistant cable.
  • Extends and locks built-in cables.
Ā 

Package Includes

Ā 

Renogy Solar Adaptor Kit

1 x

Ā 

Ā 
Renogy 10ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 10ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 10ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 10ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 20ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 20ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 20ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 20ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 30ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 30ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 30ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 30ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 40ft 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers(A Pair) Ā 
Length: 40ft AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 40ft 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 40ft AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 9in 10AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 9in AWG: 10
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 6.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.85 Min. Wall Thickness of Sheath (mm): 1.08
Number of Wires in Conductor: 84 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Renogy 9in 12AWG Adaptor Kit - Connecting Solar Panels to Charge Controllers (A Pair) Ā 
Length: 9in AWG: 12
Rating Voltage: 600/1000V Temperature: -40°F to +185°F
Normal Cross Sectional Area of the Conductor (mm2): 4.0 Diameter of Wires in Conductor (mm): 3.02±0.08
Min. Wall Thickness of Insulation (mm): 0.78 Min. Wall Thickness of Sheath (mm): 0.97
Number of Wires in Conductor: 56 IP 65 Protection
Conductor:Ā Tinned copper wire Ā 
Ā 

Warranty Information

Accessories 1-year material and workmanship warranty
Ā 
Ā 

You may also like

Thumbnail 1Thumbnail 2

REGO 3000W 12V Pure Sine Wave HF Inverter Charger Split-phase Design

$1,797.99

-65%
Thumbnail 1Thumbnail 2

BT-2 Bluetooth Module

$35.99

$12.60

-65%
Thumbnail 1Thumbnail 2

5ft ANL Fuse Cable with Double Ring Terminals for 5/16 in Lugs

$18.99

$6.65

-65%
Thumbnail 1Thumbnail 2

Battery Inverter Cables for 3/8 in Lugs

$38.99

$13.65

-65%
Thumbnail 1Thumbnail 2

Copper Battery Interconnect Cable for 5/16 in Lugs

$13.99

$4.90

-65%
Thumbnail 1Thumbnail 2

Battery to Charge Controller Tray Cables for 3/8 in Lugs

$16.99

$5.95

-65%
Thumbnail 1Thumbnail 2

1ft/2ft ANL Fuse Cable with Double Ring Terminals for 3/8 in Lugs

$9.99

$3.50